Skip to product information
1 of 5

Hro Energy

Hybrid Inverter Deye 8kW

Hybrid Inverter Deye 8kW

Regular price €3.299,99 EUR
Regular price €3.699,99 EUR Sale price €3.299,99 EUR
Sale Sold out
Tax included. Shipping calculated at checkout.

DEYE SUN-8K-SG04LP3-EU
- Approved by Elektrilevi in accordance with dirictives 2014/35/EU and 2014/30/EU of the European Parliament and of the Council
- 100% unbalanced output, each phase; Max. output up to 50% rated power
- DC couple and AC couple to retrofit existing solar system
- Max. 10pcs parallel for on-grid and off-grid operation; Support multiple batteries parallel
- Max. charging/discharging current of 240A
- 48V low voltage battery, transformer isolation design
- 6 time periods for battery charging/discharging 
- Support storing energy from diesel generator

SPECIFICATION:
Battery Input Data
Battery Type Lead-acid or Li-lon
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 190
Max. Discharging Current (A)  190
External Temperature Sensor  Yes
Charging Curve 3 Stages / Equalization
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W)  10400
Rated PV Input Voltage (V)  550 (160~800)
Start-up Voltage (V) 160
MPPT Voltage Range (V) 200-650
Full Load DC Voltage Range (V) 350-650
PV Input Current (A) 13+13
Max. PV ISC (A) 17+17
No.of MPP Trackers 2
No.of Strings per MPP Tracker 1
AC Output Data
Rated AC Output and UPS Power (W) 8000
Max. AC Output Power (W) 8800
AC Output Rated Current (A) 12.1/11.6
Max. AC Current (A) 18.2/17.4
Max. Continuous AC Passthrough (A) 45
Peak Power (off grid) 2 time of rated power, 10 S
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 3L/N/PE 220/380, 230/400Vac
Grid Type Three Phase
DC injection current (mA) THD<3% (Linear load<1.5%)
Efficiency
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency 99.90%
Protection
Integrated PV Input Lightning Protection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection
Output Over Voltage Protection DC Type II/AC Type III
Certifications and Standards
Grid Regulation CEI 0-21, VDE-AR-N 4105, NRS 097, IEC 62116, IEC 61727, G99, G98, VDE 0126-1-1, RD 1699, C10-11
Safety EMC / Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range (°C)   -40~60°C, >45°C derating
Cooling Natural cooling
Noise (dB) <45 dB
Communication with BMS RS485; CAN
Weight (kg) 33.6
Size (mm) 422W x 699.3H x279D
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 years